A leading fire alarm system manufacturer since 1995
Language

Conventional Fire Detection & Alarm System

Easy to install, the Conventional fire alarm system ODH series are compact and cost-effective solutions with reliable conventional technology in standard or installation saving, suitable for small/medium applications. 

It is the simplest type of fire alarm systems, ideal for small or medium applications such as individual offices or retail shops. Due to the lack of complexity, it requires significantly less labour to install than an addressable system and cost much less.  The use of fire and smoke detection systems results in significant reduction in fire deaths.

Factory Price Conventional Fire Alarm Control Panel ODH04
Factory Price Conventional Fire Alarm Control Panel ODH04
Characteristics And Benefits: Style B (Class B) Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devicesOne set of volt free changeover contacts operable on fireOne set of volt free changeover contacts operable on faultNon-latching zones facilityClass change input for remote controlZone and alarm disablement28V 125mA fused supply permanently available28V 300mA fused supply available for fire alarm bells or soundersPassive repeater available
Conventional Fire Alarm Control Panel, FACP/CIE, ODH32
Conventional Fire Alarm Control Panel, FACP/CIE, ODH32
Characteristics And Benefits: Comply with EN54-2&4 standardClass B Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devicesKey-switch/Password user control access8-line ×16-character large LCD display screen with multi-language menu optionsConfigurable detection zones (Latching/Non-latching/Enable/Disable) Remote panel inputs (Class Change/Evacuate/Silence Alarms/System Reset)4 alarm circuits as standard on 4 zone panel upwardsConfigurable panel outputs (Fire Routing/Fault Routing/Fire Protection)Remote panel outputs (Evacuate/Buzzer Active/Disablement Active)Programmable relay output (linkage control)Delay mode configuration options (0-180 seconds)One man Zone/Sounder walk test Up to 10 fully functional repeaters connected via 2 core RS485 data cable Extensive configuration and programming options to cater for individual requirements
Conventional Fire Alarm Control Panel ODH1004/1008/1016
Conventional Fire Alarm Control Panel ODH1004/1008/1016
Characteristics And Benefits: 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs).– All zones accept two-wire smoke detectors and any normally-open contact devices.– Zones 1 – 4/8/16 configured as general alarm zones.All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).NACs may be programmed:– Silenceable– Non-Silenceable.– Auto-Silence (program 5 to 20 minutes)1.25 amps of NAC power3.0 amps of total system powerAlarm, Trouble and Supervisory, Form-C relays standard.24-volt operationResettable four-wire smoke detector power @ 500 MaNon-resettable power @ 500 mA.Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).One-man walk-test programmable for silent or audible test.Disable/Enable control per IDCReverse polarity protectionControl buttons:– Mode– Test– ACK (Acknowledge) Alarm Silence– ResetMeet UL864, EN-54 standard.LED indicators:– AC Power (green & yellow LED)– Fire Alarm (red LED)– Trouble (yellow LED)– Supervisory (yellow LED)– Signal Silence (yellow LED)– Battery Power (green & yellow LED)– Zone Disable (yellow LED)– NAC Fault (yellow LED)– NAC Disable (yellow LED)– 4/8/16 Zone Alarm (one for each zone) (red LED)– 4/8/16 Zone Trouble (one for each zone) (yellow LED)– Earth Fault (on circuit board)– Battery Fault (on circuit board)– Charger Fault (on circuit board)
Conventional Fire Alarm Control Panel ODH08/16 With 8/16 Zone
Conventional Fire Alarm Control Panel ODH08/16 With 8/16 Zone
Characteristics And Benefits: Style B (Class B) Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devices  One set of volt free changeover contacts operable on fire  One set of volt free changeover contacts operable on fault  Non-latching zones facility  Class change input for remote control  Zone and alarm disablement  28V 1.5A fused supply permanently available  Two 28V 300mA fused supplies available for fire alarm bells or sounders  Passive repeater available 
High Accuracy Conventional Heat Detector Fixed Temperature OT306 OEM
High Accuracy Conventional Heat Detector Fixed Temperature OT306 OEM
Characteristics And Benefits: Transnormal thin design for thickness , just 38mm.Adopt SMT technology, firmly, high secure and antijamming.Special methods for damp-proof, antisepsis and mildew-proof.Flame retardant thermoplasticEasy plug-in of the head to baseSEMS screws for easy wiring2-wire without polarity
Conventional Resettable Manual Call Point OA302
Conventional Resettable Manual Call Point OA302
Characteristics And Benefits: Integrated with on-and-off input signalSending signal to Intelligent Monitoring Modular for processing or activate the fire bell and other fire protection equipmentTest key includedSimple structureDual wiring terminals for Normal open or Normal close circuitEasy installation and wiringComply with Standard: GB19880-2005
Conventional Fire Strobe Light, 24VDC Operated, AGB01
Conventional Fire Strobe Light, 24VDC Operated, AGB01
Characteristics And Benefits: Combining of multi-sensor fire detection and image recognition technology, the application scenario artificial intelligence portrait technology, continuously self-learning, and optimization and adjustment automatically of sensitivities in different places, it can greatly reduce the high rate of false alarm of traditional fire detector, that will make our users No hassles, No problems, No worries.Back Box ABB01: ABB01 was designed as waterproof embedded back box suit with AGB01 fire strobe light which is used to be installed at hotels, apartments, hospitals, commercial buildings, residential buildings, shopping malls or wherever visible alarms are required. It utilizes a rubber sealing ring to prevent water entry, rated at IP66. Material: Steel paint.Dimensions: 128×88×48 mm.
Conventional Sounder Strobe 2-wire 24VDC Operated OS109
Conventional Sounder Strobe 2-wire 24VDC Operated OS109
Characteristics And Benefits: It generates strong audible and visual alarm signal to warn people to evacuate from the fire. 2-wire 24VDC operated.
Conventional Manual Call Point Pull Station Resettable OA301
Conventional Manual Call Point Pull Station Resettable OA301
Characteristics And Benefits: Compatible with all the conventional fire alarm control panel Can be reset by key without use a new glass 470 Ohm resistanceEasy surface mounting Base included
Remote LED Alarm Indicator RM111 Factory Price China
Remote LED Alarm Indicator RM111 Factory Price China
Characteristics And Benefits: 2-wireRemote LEDRed Color 
Conventional Sounder Base 6008 Compatible With OT602/603/306
Conventional Sounder Base 6008 Compatible With OT602/603/306
Characteristics And Benefits: Adds an audible alarm output function to a detector Can be used with a sensor as a detector base or stand alone as a sounderHigh sound pressure level, low power consumption with wide operating voltage Both wall or ceiling mounting Easy installation and wiringSelectable three different tones with a DIP switchComply with EN54, UL268 and UL464 standard
Conventional Infrared Reflective Beam Smoke Detector BD106
Conventional Infrared Reflective Beam Smoke Detector BD106
Characteristics And Benefits:  Wide operating voltage range, big monitoring areas.Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.Built-in microprocessor enables intelligent judgment of fire alarm and fault.The detector can calibrate automatically, which ensures that one person complete adjustment in short time. It's also convenient to operate.Self-diagnosis function can monitor the inner fault.Automatic compensation for factors weakening received signals, such as dust contamination, positional excursion and ageing transmitter.It has passive output contacts for fire alarm and fault.Two sensitivity levels can be set in field.The detector's optical pathway is designed with strong anti-interference ability.SMT processing technology.Attractive and decent appearance.
Choose a different language
Current language:English

Send your inquiry