A leading fire alarm system manufacturer since 1995
Language

Control Panel

The Conventional Fire Alarm Control Panel ODH series are 24volt, 2-32 zone, Class B, Conventional Fire Alarm Control Panels. Designed exclusively to meet the latest market requirements and microprocessor technology, they come with stand-by batteries (two sealed acid storage batteries) and reserved space for installation, functioning of operation indication, fault indication, alarm indication and cable checking for short circuit or broken circuit.
The highly cost-effective ODH series are the simplest type of fire alarm systems, ideal for small or medium applications such as individual offices or retail shops. Due to the lack of complexity, it requires significantly less labour to install than an addressable system and cost much less.


Factory Price Conventional Fire Alarm Control Panel ODH04
Factory Price Conventional Fire Alarm Control Panel ODH04
Characteristics And Benefits: Style B (Class B) Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devicesOne set of volt free changeover contacts operable on fireOne set of volt free changeover contacts operable on faultNon-latching zones facilityClass change input for remote controlZone and alarm disablement28V 125mA fused supply permanently available28V 300mA fused supply available for fire alarm bells or soundersPassive repeater available
Conventional Fire Alarm Control Panel, FACP/CIE, ODH32
Conventional Fire Alarm Control Panel, FACP/CIE, ODH32
Characteristics And Benefits: Comply with EN54-2&4 standardClass B Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devicesKey-switch/Password user control access8-line ×16-character large LCD display screen with multi-language menu optionsConfigurable detection zones (Latching/Non-latching/Enable/Disable) Remote panel inputs (Class Change/Evacuate/Silence Alarms/System Reset)4 alarm circuits as standard on 4 zone panel upwardsConfigurable panel outputs (Fire Routing/Fault Routing/Fire Protection)Remote panel outputs (Evacuate/Buzzer Active/Disablement Active)Programmable relay output (linkage control)Delay mode configuration options (0-180 seconds)One man Zone/Sounder walk test Up to 10 fully functional repeaters connected via 2 core RS485 data cable Extensive configuration and programming options to cater for individual requirements
Conventional Fire Alarm Control Panel ODH1004/1008/1016
Conventional Fire Alarm Control Panel ODH1004/1008/1016
Characteristics And Benefits: 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs).– All zones accept two-wire smoke detectors and any normally-open contact devices.– Zones 1 – 4/8/16 configured as general alarm zones.All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).NACs may be programmed:– Silenceable– Non-Silenceable.– Auto-Silence (program 5 to 20 minutes)1.25 amps of NAC power3.0 amps of total system powerAlarm, Trouble and Supervisory, Form-C relays standard.24-volt operationResettable four-wire smoke detector power @ 500 MaNon-resettable power @ 500 mA.Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).One-man walk-test programmable for silent or audible test.Disable/Enable control per IDCReverse polarity protectionControl buttons:– Mode– Test– ACK (Acknowledge) Alarm Silence– ResetMeet UL864, EN-54 standard.LED indicators:– AC Power (green & yellow LED)– Fire Alarm (red LED)– Trouble (yellow LED)– Supervisory (yellow LED)– Signal Silence (yellow LED)– Battery Power (green & yellow LED)– Zone Disable (yellow LED)– NAC Fault (yellow LED)– NAC Disable (yellow LED)– 4/8/16 Zone Alarm (one for each zone) (red LED)– 4/8/16 Zone Trouble (one for each zone) (yellow LED)– Earth Fault (on circuit board)– Battery Fault (on circuit board)– Charger Fault (on circuit board)
Conventional Fire Alarm Control Panel ODH08/16 With 8/16 Zone
Conventional Fire Alarm Control Panel ODH08/16 With 8/16 Zone
Characteristics And Benefits: Style B (Class B) Initiating Device Circuits (IDCs) accept two-wire smoke detectors and any normally-open contact devices  One set of volt free changeover contacts operable on fire  One set of volt free changeover contacts operable on fault  Non-latching zones facility  Class change input for remote control  Zone and alarm disablement  28V 1.5A fused supply permanently available  Two 28V 300mA fused supplies available for fire alarm bells or sounders  Passive repeater available 
Conventional Fire Alarm Repeater Panel RP1016 China
Conventional Fire Alarm Repeater Panel RP1016 China
Characteristics And Benefits: The LED Repeater is a Remote Annunciator to display fire alarm or fault information of Orena ODH1000 conventional fire alarm system.
Choose a different language
Current language:English

Send your inquiry