A leading fire alarm system manufacturer since 1995
Language

Gas Extinguishing Control System

Fire detection and extinguishing control panel process results detected by fire detectors and  manual call point, set off alarms to extinguishant buttons and related equipment. It continuously monitors extinguishing systems for functionality and trigger them electrically if necessary.
The control panel is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.

Compatible with wide range of fire detection field devices, ease of use, and full functions, Orena’s Gas Extinguishing System is cost-effective. Control panel ODM04 has a number of programmable inputs and outputs for interfacing with other fire systems. It is suitable for almost small and medium flooding area applications and includes a range of control options and devices.

Gas Extinguishing Control Panel ODM04 With 4 Zones
Gas Extinguishing Control Panel ODM04 With 4 Zones
Characteristics And Benefits: Class B Initiating Device Circuits (IDCs) 4 zones accept conventional detectors and any normally open contact device 2 Class B Notification Appliance Circuits (NACs) One Form-A Alarm Relay One Form-A Fault Relay Two Form-A Stage Relay 3.0 amps of system power Max 30 conventional detectors in one zone Each Zone can be disabled Sound output can be disabled Manual active sound output enabled Can connect max 32 repeater panels by RS485 communication port Panel Dimensions (mm): 383*295*87(L*W*D)Panel Weight [Without Batteries]: 5.0kg
Emergency Extinguishant Button (Start/ Abort) QT115
Emergency Extinguishant Button (Start/ Abort) QT115
Characteristics And Benefits: Operating Voltage Range: 9 to 28 Volts Non-polarized Switch Contact Capacity: 2Amp @24VDC Maximum Alarm Current: ≤50mA @ 24 VDC Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Panel of Press: Recoverable Weight: 123g Diameter: 87*87*49(L*W*D)
Maintenance Switch (Auto/ Manual) WH116
Maintenance Switch (Auto/ Manual) WH116
Characteristics And Benefits: Operating Voltage Range: 9 to 28 Volts Non-polarized Switch Contact Capacity: 5Amp @30Vdc Maximum Alarm Current: ≤20mA @ 30 Vdc Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Protection level: IP65 Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Material: ABS Dimensions(MM): 115*90*54(L*W*D) Weight: 237g
Release Warning Indicator FQ119
Release Warning Indicator FQ119
Characteristics And Benefits: Operating Voltage Range: 9 to 28 Volts Non-polarized Flash Intensity: >75CD Maximum Alarm Current: ≤90mA @ 30 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Flash Period: 1.5 Second Material: ABS Diameter: 295*120*28(L*W*D) Weight: 293g
High Accuracy Conventional Heat Detector Fixed Temperature OT306 OEM
High Accuracy Conventional Heat Detector Fixed Temperature OT306 OEM
Characteristics And Benefits: Transnormal thin design for thickness , just 38mm.Adopt SMT technology, firmly, high secure and antijamming.Special methods for damp-proof, antisepsis and mildew-proof.Flame retardant thermoplasticEasy plug-in of the head to baseSEMS screws for easy wiring2-wire without polarity
Conventional Sounder Strobe 2-wire 24VDC Operated OS109
Conventional Sounder Strobe 2-wire 24VDC Operated OS109
Characteristics And Benefits: It generates strong audible and visual alarm signal to warn people to evacuate from the fire. 2-wire 24VDC operated.
High Accuracy Conventional Photoelectric Smoke Detector OT302 OEM
High Accuracy Conventional Photoelectric Smoke Detector OT302 OEM
Characteristics And Benefits: Transnormal thin design for thickness , just 45mm.Adopt SMT technology, firmly, high secure and antijamming.Special methods for damp-proof, antisepsis and mildew-proof.With inner mothproof net and shield coverFlame retardant thermoplasticEasy plug-in of the head to baseSEMS screws for easy wiring2-wire without polarity
Choose a different language
Current language:English

Send your inquiry